The Counter unit counts up (or down, depending on the '''step''' value) from a '''start''' value to a '''finish''' value. A trigger at the input of the unit (i.e. coming from the left) will cause add the step value to the current output value of the unit. If the resulting output value exceeds the '''finish''' value then depending on the '''Wrap?''' setting, the Counter's output value will either wrap back around to the '''start''' value, or, stop. A trigger on the '''reset''' parameter will cause the output value to return the '''start''' value.
 
== Special Menu Items ==
 
=== Wrap? ===
 
* '''yes''': Automatically reset to the start value once the output value reaches the '''finish''' value.
* '''no''': Stop at the finish value and wait for a manual reset.
 
=== Process Rate ===
 
* '''frame''': Process triggers and update the output value at the global frame rate (about 400Hz).
* '''sample''': Process triggers and update the output value at the global sample rate (48kHz or 96kHz).
== Parameters ==