=== SYNC message on startup ===
 +
 +
If you get this message on the ER-102, then here is a checklist:
 +
 +
# Check that the ER-101 is powering on.  If properly powering up, the ER-101 will always perform an up/down sweep of the digit displays and then display the firmware version, regardless of whether it it conected to the ER-102.  The usual culprit for an ER-101 not powering up is an incorrect setting of the 5V supply switch.  Try setting it to REG.
 +
# Triple check that the orientation of the ER-101-to-ER-102 expansion cable is correct.  The first page of the ER-102 manual has a detailed diagram for your reference.
 +
# If you get here, then it is highly likely that the ER-102 expansion cable was inadvertently plugged into the case power at some point and thus damaging the ER-102's ability to communicate with the ER-102.  This requires a repair.  Please contact me to setup that up.

Latest revision as of 19:04, 18 January 2021

Pitfall.png
Very little information has been added to the ER-102 section of this wiki yet. Please refer to the ER-102 pages over on the main website or ask on the forum.


Known Issues and Feature Requests

Panel Design Files: er-102-panel.zip

SYNC message on startup

If you get this message on the ER-102, then here is a checklist:

  1. Check that the ER-101 is powering on. If properly powering up, the ER-101 will always perform an up/down sweep of the digit displays and then display the firmware version, regardless of whether it it conected to the ER-102. The usual culprit for an ER-101 not powering up is an incorrect setting of the 5V supply switch. Try setting it to REG.
  2. Triple check that the orientation of the ER-101-to-ER-102 expansion cable is correct. The first page of the ER-102 manual has a detailed diagram for your reference.
  3. If you get here, then it is highly likely that the ER-102 expansion cable was inadvertently plugged into the case power at some point and thus damaging the ER-102's ability to communicate with the ER-102. This requires a repair. Please contact me to setup that up.