Line 3: | Line 3: | ||
* In trigger mode, steps with duration of 1 do not produce changes in CV ([https://forum.orthogonaldevices.com/t/duration-1-in-trigger-mode-doesnt-output-cv-changes/4061?u=odevices thread]). | * In trigger mode, steps with duration of 1 do not produce changes in CV ([https://forum.orthogonaldevices.com/t/duration-1-in-trigger-mode-doesnt-output-cv-changes/4061?u=odevices thread]). | ||
* Copy/pasting patterns (or more?) between snapshots is not reliable ([https://forum.orthogonaldevices.com/t/copy-pattern-through-snapshot/2330?u=odevices thread]) | * Copy/pasting patterns (or more?) between snapshots is not reliable ([https://forum.orthogonaldevices.com/t/copy-pattern-through-snapshot/2330?u=odevices thread]) | ||
+ | * CONFIG.INI > user-transition > Transitions configured to be triggered on track-{1,2,3,4} rewinding are not working properly. The bug is that the actual track used is off by 1 from the configured track. So for example, user-transition = track-1 will cause track #2 to be used and so on. ([https://forum.orthogonaldevices.com/t/track-specific-user-transition-of-parts-not-working/4636?u=odevices thread]) | ||
== Feature Requests == | == Feature Requests == |
Latest revision as of 03:22, 21 July 2020
Issues
- In trigger mode, steps with duration of 1 do not produce changes in CV (thread).
- Copy/pasting patterns (or more?) between snapshots is not reliable (thread)
- CONFIG.INI > user-transition > Transitions configured to be triggered on track-{1,2,3,4} rewinding are not working properly. The bug is that the actual track used is off by 1 from the configured track. So for example, user-transition = track-1 will cause track #2 to be used and so on. (thread)
Feature Requests
The majority of the requests listed here were compiled from requests made by users over at the forum. |
- CONFIG.INI parameter to set trigger duration (currently 0.5ms) when note repeat is enabled on a step. (thread)
- CONFIG.INI parameter to set reset slop time (current default is 0.5ms) to account for sequencers that output signals later with respect to the clock. (thread)
- CONFIG.INI parameter to change the behavior of the track config of the note display's root note to also offset the output voltage by the same amount. (thread)
- Allow copying of just the GROUP MODIFIER (thread)